SHENGLONG’S INDEPENDENTLY DEVELOPED iPANEL PLATFORM
AI-iPanel Compact Intelligent Switchgear
Shenglong’s low-voltage switchgear platform combining compact cabinet engineering, integrated electrical monitoring, and configurable AI-assisted operation.
Building on the independently developed iPanel platform, AI-iPanel introduces further structural optimisation, including a 500 mm feeder-cabinet option with 3P devices and recommended individual drawer currents of 400 A or below, with main busbar configurations up to 4000 A.
We coordinate cabinet layout, electrical performance, monitoring, and software functions as a project solution.

Compact Feeder Selection and Copper Efficiency
AI-iPanel uses a structure between iPanel-L and iPanel-E in complexity, combining simplified construction with compact feeder arrangements. Fixed and withdrawable arrangements are available.
The 500 mm-wide feeder option requires 3-pole (3P) switching devices. Individual drawer circuits are recommended at 400 A or below. A 4-pole (4P) arrangement requires a wider cabinet. Drawer quantity, component dimensions, cable space, temperature rise, and enclosure protection are checked for the proposed configuration. The 400 A recommendation concerns an individual drawer circuit, not the main busbar rating.
Front cabling and maintenance can be configured for near-wall installation, but require increased cabinet width. Do not assume that the near-wall arrangement and the 500 mm width apply to the same configuration.
U-section busbars can be selected for high-current arrangements to reduce copper usage and material cost. The applicable construction and economic benefit are assessed for the required electrical and thermal ratings.
Compact Hardware, Connected Information, AI-Assisted Operation
Cabinet Engineering
More compact feeder arrangements and organised functional units address switchroom space, component access, wiring, and maintenance requirements.
Electrical and Intelligent-Function Verification
Supporting documents cover electrical assembly performance and selected monitoring, protection, and AI detection/control functions. The equipment, software, data inputs, and control scope are specified for each project.
Compact DesignTypical ApplicationsTechnical DataAI ApplicationsMonitoringVerified PerformanceiPanel Family
Compact and Modular Design
A 500 mm-wide feeder cabinet is available for the selected arrangement. Compared with the illustrated 600 mm cabinet, six 500 mm cabinets occupy the same 3000 mm lineup width as five 600 mm cabinets. Total room area and circuit capacity also depend on depth, access, cable routes, and the selected equipment.

Organised Functional Units
Integrated current-transformer modules and an optimised primary/secondary component layout organise wiring and access within the functional unit.
Drawer mechanisms, current ratings, cable interfaces, and unit sizes are selected together. Cabinet width is confirmed for each function rather than applied to every cabinet in the lineup.
Circuit-Breaker Cabinets
Incoming, outgoing, and bus-coupling duties with fixed or withdrawable devices; ratings up to 4000 A according to the selected configuration.
Feeder and Drawer Arrangements
High-current feeder circuits up to 2000 A and selected drawer circuits up to 630 A, with widths and thermal limits matched to the equipment.
Fixed-Compartment Options
Fixed-compartment circuits up to 630 A in selected 500 / 600 / 800 mm cabinet arrangements.
Reactive Power Compensation
Compensation configurations up to 500 kvar, with steps, protection, switching, and harmonic treatment selected for the load.
Typical Applications
Space-Constrained Switchrooms
Projects where selected narrower feeder cabinets can improve lineup planning, subject to cable access, operating clearance, and the required circuit schedule.
Manufacturing and Motor Control
Production distribution and motor circuits where maintenance teams need electrical status, fault indications, and a coordinated monitoring interface.
Commercial and Institutional Facilities
Distribution systems seeking centralised operating information, historical data, alarms, and planned expansion.
Energy and Operations Management
Sites evaluating load forecasting, transformer loading, demand patterns, and authorised optimisation within the selected software solution.
Technical Specifications
Electrical ratings are selected for the operating voltage, frequency, circuit function, enclosure, and cooling arrangement.
| Parameter | Specification |
|---|---|
| Application | Power distribution and motor control |
| Installation | Indoor |
| Main busbar rated current | 400–1600 A and 1600–4000 A configurations at 50 Hz; applicable 60 Hz ratings depend on the circuit and configuration |
| Rated operational voltage | 127, 208, 220, 380, 400, 415, 440, 460, 480, 500, 540, 660 and 690 V AC, depending on configuration |
| Rated insulation voltage | 1000 V for incoming and feeder circuits; 800 V for control circuits for the selected verified configuration |
| Rated frequency | 50/60 Hz; confirm the current rating for the selected frequency |
| Short-time withstand current: 400–1600 A configurations | 50 kA at 127/208/220/380/400 V; 35 kA at 415/440/460/480/500/540/660/690 V. Required withstand duration is confirmed for the selected assembly. |
| Short-time withstand current: 1600–4000 A configurations | 85 kA at 127/208/220/380/400 V; 65 kA at 415/440/460/480/500/540/660/690 V. Required withstand duration is confirmed for the selected assembly. |
| Enclosure protection | Options include IP20, IP30, IP31, IP32, IP40, IP41, IP42, IP43, IP44 and IP54; configuration-dependent |
| Mechanical impact protection | IK10 for the selected verified configuration |
| Internal arcing test | 690 V, 100 kA for 0.5 s, arcing class A, for the tested 4000 A assembly |
| Monitoring and AI functions | Selected according to project requirements and the configured monitoring and control system |
Cooling and Assembly Rating
The verified 4000 A temperature-rise configuration includes six rear-door fans operating during the test. Cooling is part of the rated assembly design. Different ambient temperatures, ventilation, or cabinet arrangements require confirmation of the applicable current rating.
Rating selection: Internal-arcing performance and short-time withstand are separate characteristics. Select voltage, current, fault duty, withstand duration, enclosure protection, and cooling as one configuration.
AI Applications for the Operating Team
The AI-iPanel solution supports AI-assisted operation and maintenance, fault warning and diagnostic support, load forecasting, and operating optimisation. Available applications include:
- Reviewing equipment status and historical operating information across the connected distribution system.
- Identifying abnormal conditions and supporting investigation and maintenance planning.
- Forecasting load changes using operating data.
- Analysing transformer loading and supporting load allocation and time-of-use operating strategies.
The quotation defines the software version, enabled AI modules, required data, deployment and connectivity, interfaces, and acceptance requirements. Forecasting and analysis depend on the available operating data. Any automatic control requires the agreed control hardware, permissions, and operating interlocks; analytical functions do not replace the protection system.

Integrated Monitoring and System Visibility
Standard iDrip Monitoring
Standard supply includes Shenglong’s iDrip monitoring system, with an English-language interface and Modbus RTU communication. The software version is matched to each iPanel series.
- Incoming cabinets: current, voltage, active and reactive power, energy, harmonics, and circuit-breaker open/closed status.
- Outgoing circuits: switch-status monitoring is normally provided. Harmonic monitoring is not part of the normal outgoing-circuit scope; any additional outgoing measurements are agreed in the project schedule.
- Remote switching: primarily provided for incoming air circuit breakers (ACBs), with the controlled circuits and interlocks defined in the project scheme. Remote operation of MCCBs or MCBs requires suitable motor operators, contactors, or corresponding control circuits.
Voice control, temperature monitoring, busbar temperature monitoring, and other additional modules are optional and require separate customer confirmation. The quotation identifies the data points, display arrangement, software functions, and controlled circuits.

Performance Verification and Technical Support
Electrical Assembly Performance
Type-test documentation covers 400–1600 A and 1600–4000 A configurations, with voltage-dependent withstand values. Applicable electrical and CQC documentation is selected for the proposed assembly.
Internal-Arcing Performance
The tested 4000 A assembly has internal-arcing verification at 690 V, 100 kA for 0.5 seconds, arcing class A. Applicable construction and test conditions are reviewed for the project.
Monitoring and AI Functions
Intelligent-function verification includes selected remote adjustment, measurement, control, signalling, power-quality monitoring, energy statistics, safety warnings, alarm protection, and AI detection/control.
Special Service Requirements
High-altitude insulation verification is available for the corresponding tested configuration. Actual altitude, thermal ratings, ventilation, and site requirements are reviewed separately.
We provide applicable technical and verification documents for project review. Electrical tests and intelligent-function tests address their respective equipment and functions; they do not establish a guaranteed AI outcome or blanket coverage for every software configuration.
Installation and Service Conditions
AI-iPanel is intended for indoor installation. Provide ambient temperature, humidity, altitude, corrosion exposure, seismic requirements, and available ventilation during enquiry.
Typical cabinet height is 2200 mm. Width and depth vary by function; cable entry options include bottom, top, or side according to configuration. Final lineup dimensions, installation clearances, foundation fixing, and maintenance access are provided in the project drawings.
Selecting Within the iPanel Family
iPanel-L
Elaborate cabinet and plug-in connection design, an independent busbar arrangement, and higher-protection options. Rear maintenance access is required.
iPanel-E
Simplified, cost-conscious construction with iPanel styling and iDrip monitoring. Wider front-access arrangements can support near-wall installation.
AI-iPanel
Compact feeder options, U-section busbars for selected high-current designs, and AI applications. The 500 mm feeder requires 3P devices; drawer circuits are recommended at 400 A or below.
iPanel-M
Shenglong’s medium-voltage platform, with its own construction, ratings, and verification. The low-voltage comparisons above do not apply to iPanel-M.
Circuit-Breaker Choice and Project Delivery
All three low-voltage iPanel series can accommodate mainstream circuit-breaker brands, including ABB, Siemens, Schneider Electric, and Shenglong, subject to the selected device dimensions and cabinet arrangement. Shenglong circuit breakers offer a cost-effective project option. For iPanel-L and iPanel-E, 3P or 4P devices do not by themselves impose the AI-iPanel 500 mm-width restriction.
English drawings and operation and maintenance manuals can be provided. Overseas on-site services are quoted separately, with the service scope agreed for the project.
Project Engineering and Documentation
Send your single-line diagram, circuit schedule, and monitoring requirements. We will review the electrical assembly, cabinet dimensions, cooling, software, data interfaces, control scope, and applicable documents together.
Plan Your Project with AI-iPanel
- Project location, application, quantities, and delivery schedule.
- Operating voltage, frequency, circuit currents, and fault duty.
- Single-line diagram, circuit schedule, available space, and cable routes.
- Enclosure protection, internal separation, and cooling requirements.
- Required measurements, alarms, historical data, and supervisory interfaces.
- AI use cases, available data, deployment needs, and acceptance criteria.
- Remote-control permissions, operating interlocks, and software scope.
- Ambient conditions, altitude, seismic requirements, and ventilation.
If you are still planning your project, send the information you have. We can discuss the remaining details with you.
Prefer email? info@shenglong-hub.com
Ratings, intelligent functions, and software apply to their respective configurations. Final equipment, documentation, interfaces, and supply scope are established in the project technical agreement.