SHENGLONG’S INDEPENDENTLY DEVELOPED iPANEL PLATFORM
iPanel-M Medium-Voltage Switchgear
Shenglong’s independently developed metal-clad switchgear platform for medium-voltage power distribution, circuit protection, and configurable monitoring.
Developed from established medium-voltage cabinet engineering with Shenglong’s own structural and control innovations, iPanel-M complements the low-voltage iPanel family as a coordinated product choice for your power distribution project.
Choose standard iPanel-M or the 650 mm-wide iPanel-M650 according to current rating, fault duty, available space, and operating requirements.

Design FeaturesTypical ApplicationsCabinet OptionsTechnical DataMonitoringSafety and PerformanceiPanel Family
Independent Engineering for Medium-Voltage Distribution
Metal-Clad Compartmentalisation
Dedicated compartments organise the main busbars, circuit breaker, cable connections, and low-voltage protection/control equipment.
Withdrawable Switching Equipment
Defined truck positions and operating interlocks support the selected switching and maintenance sequence. Compatible truck and component arrangements are confirmed for the supplied equipment.
Standard and Compact Choices
Standard cabinet widths accommodate higher-current configurations. M650 provides a 650 mm-wide alternative for selected duties up to 1250 A and 31.5 kA.
Protection and Connected Operation
Protection relays, indication, measurements, temperature monitoring, and selected operating controls are coordinated with the project protection and supervisory systems.
Typical Applications
Manufacturing and Industrial Plants
Medium-voltage incoming supplies, feeders, transformer circuits, and bus sections in automotive, process, petrochemical, and general industrial facilities.
Commercial and Public Buildings
Distribution for commercial developments, hospitals, campuses, and public facilities where the required voltage and fault duty match the selected equipment.
Data Centres and Infrastructure
Medium-voltage distribution supporting data centres, computing facilities, and infrastructure, with protection, operating sequences, and monitoring defined for the project.
Power Systems and Space-Constrained Projects
Standard or compact cabinets selected around circuit duties, available switchroom space, cable routes, and future layout requirements.
Standard and Compact Cabinet Options
iPanel-M Standard
Cabinet widths of 800 mm and above, with electrical options up to 4000 A and 50 kA / 4 s according to the selected construction. We match cabinet size, breaker, cable interfaces, and protection to the required duty.
iPanel-M650
Enhanced insulation and compact construction provide a 650 mm-wide cabinet option up to 12 kV, 1250 A, and 31.5 kA. Consider this arrangement where space and circuit duties favour a narrower lineup.
Technical Comparison
| Parameter | iPanel-M Standard | iPanel-M650 |
|---|---|---|
| Cabinet width | 800 mm and above | 650 mm |
| Rated voltage | 12 kV | 12 kV |
| Rated current | Up to 4000 A | Up to 1250 A |
| Rated short-time withstand current | Up to 50 kA / 4 s | Up to 31.5 kA / 4 s |
| Rated peak withstand current | Up to 125 kA | Up to 80 kA |
| Internal-arcing options by configuration | 50 kA / 1 s | 31.5 kA / 1 s |
| Seismic classification | AG5 | AG5 |
Configuration selection: Electrical and internal-arcing ratings depend on the selected cabinet construction. We confirm the rating combination, installation requirements, and applicable technical documents in the project proposal.
Common Specifications and Service Conditions
| Parameter | Specification |
|---|---|
| Rated frequency | 50 Hz |
| Power-frequency withstand voltage, 1 min — phase-to-earth and phase-to-phase | 42 kV |
| Power-frequency withstand voltage, 1 min — isolating distance | 48 kV |
| Lightning impulse withstand voltage — phase-to-earth and phase-to-phase | 75 kV |
| Lightning impulse withstand voltage — isolating distance | 85 kV |
| Ambient temperature | −15°C to +40°C; daily average up to +35°C |
| Altitude | Up to 1000 m; high-altitude configuration subject to project review; supporting tests include a 4500 m configuration |
| Relative humidity | Daily average up to 95%; monthly average up to 90% |
| Enclosure protection | IP4X |
| Compartment protection | IP2X |
| Cabinet dimensions (W × D × H) | Standard: 800 or 1000 × 1500 × 2300 mm; M650: 650 × 1500 × 2300 mm |
For overhead incoming connections, the catalogue lists a depth of 1660 mm. Final dimensions, clearances, ventilation, cable bending space, and pressure-relief arrangements follow the approved project drawings.
For 60 Hz systems, temperatures above the normal range, or altitudes above 1000 m, provide the actual conditions so that ratings and insulation can be reviewed.
Monitoring and Operating Options
Electrical Measurements and Status
Selected voltage/current data, switch position indications, protection signals, and alarm information integrated with the project monitoring system.
Equipment Condition
Optional temperature monitoring, circuit-breaker condition information, and arc protection, with sensors and data points defined for the selected cabinet.
Motorised and Sequenced Operation
Optional motorised mechanisms and programmed switching sequences. Interlocks, operating permissions, and control logic are agreed during technical design.
Supervisory Integration
Communication interfaces, protocol requirements, local displays, software, and remote-control scope are defined for the project rather than assumed as standard cabinet features.
Safety and Performance
iPanel-M combines verified electrical performance with metal-clad compartmentalisation, operating interlocks, and project-selected environmental protection.
Electrical Performance
Insulation, temperature-rise, and short-circuit performance are verified for the relevant iPanel-M configurations. We select voltage, current, withstand duty, and switching equipment to match your distribution system.
Internal-Arc Protection
Compartmentalised construction and coordinated pressure-relief arrangements form part of the internal-arc protection design. Internal-arcing performance has been verified at 31.5 kA for 1 second for the corresponding construction.
Seismic and Mechanical Performance
iPanel-M configurations have undergone AG5 seismic and IK07 mechanical-impact verification. Cabinet fixing and foundation interfaces are engineered for the project installation.
High-Altitude Solutions
High-altitude configurations have been tested at 4500 m. We coordinate insulation, thermal performance, and equipment ratings for the actual site altitude and ambient conditions.
Performance ratings apply to the selected construction and installation conditions. We provide the relevant technical documents with your project proposal.
Installation and Project Engineering
We coordinate the single-line diagram, cabinet functions, switchroom arrangement, maintenance access, cable entry, foundation interfaces, earthing, and pressure-relief route. Send your room layout and cable information with the equipment schedule.
Protection settings, switching sequences, interlocks, and supervisory integration are developed around the project operating strategy.
The Shenglong iPanel Family
iPanel-M | Medium Voltage
Shenglong’s independent medium-voltage platform with standard and compact cabinet options. Select its own ratings and verification for the project.
iPanel-L | Low-Voltage Platform
Modular distribution and motor control with independent busbars, maintainable functional units, and configurable monitoring. Explore iPanel-L →
iPanel-E | Optimised Low-Voltage Series
Selected electrical performance, local displays, and connected operating functions within the iPanel family. Explore iPanel-E →
AI-iPanel | Compact and AI-Enabled
Further low-voltage compactness and optional Shenglong AI applications, with software and control scope defined separately. Explore AI-iPanel →
Technical Documentation and Project Support
We support your project with equipment selection, arrangement drawings, protection and monitoring coordination, installation interfaces, and relevant certification and test documents. Send your single-line diagram and equipment schedule to start the discussion.
Plan Your Project with iPanel-M
- Location, application, quantities, and delivery schedule.
- System voltage, equipment rated voltage, frequency, and fault duty.
- Single-line diagram and circuit schedule.
- Standard or M650 cabinet preference and available room space.
- Incoming/outgoing cable connections and busbar interfaces.
- Protection, metering, interlocking, monitoring, and operating sequences.
- Required internal-arcing, seismic, and special-environment performance.
- Altitude, temperatures, humidity, and other site conditions.
If you are still planning your project, send the information you have. We can discuss the remaining details with you.
Prefer email? info@shenglong-hub.com
Ratings, features, and test results apply to their corresponding configurations. Final equipment, functions, and documentation are established in the agreed project technical schedule.