YB Series Box-Type Substation

SHENGLONG PREFABRICATED SUBSTATIONS

YB Series Prefabricated Substation

A complete HV/LV power supply unit integrating high-voltage switchgear, a distribution transformer, and low-voltage switchgear within a compartmentalised enclosure.

Shenglong YB substations are available with 12 or 24 kV HV units, a 0.4 kV LV system, and transformer capacities from 630 to 2500 kVA. Factory assembly, internal wiring, and testing simplify site installation.

We configure the supply scheme, transformer, outgoing circuits, enclosure, and monitoring to suit your project.

Discuss Your ProjectTechnical Specifications

Shenglong YB series outdoor prefabricated substation
YB box-type substation. Enclosure and equipment arrangements are selected for each project.

Product FeaturesTypical ApplicationsTechnical DataConfigurationMonitoringInstallationService Conditions

Product Features

Factory-Assembled Power Supply Unit

The HV unit, transformer, LV unit, and auxiliary systems are assembled and internally wired in the factory. Site work includes positioning, external connections, inspections, and commissioning.

Compartmentalised Construction

Separate HV, transformer, and LV compartments provide dedicated access and equipment space. Triangular, row, and in-line layouts accommodate different capacities and site requirements.

Outdoor Enclosure

IP33D enclosure protection is available as standard, with IP44 optional. Enclosure materials include coated aluzinc steel, aluminium alloy, and cement-based composite panels.

Transformer Cooling

Ventilation louvres and natural convection remove heat, with temperature-controlled fans operating when required. Oil-immersed and dry-type transformers are available.

High-Altitude Configurations

Dedicated configurations have undergone type-test verification at 4500 m. Actual altitude, insulation, cooling, and transformer requirements are reviewed for each high-altitude project.

Integrated Monitoring Options

Optional monitoring terminals provide electrical measurements, equipment status, alarms, and supervisory communication. Additional temperature sensing, video, and access control can be included.

Typical Applications

Urban Distribution

Municipal roads, district distribution installations, street lighting, and landscape lighting supplies.

Residential and Commercial Projects

Residential communities, commercial complexes, industrial parks, schools, and hospitals.

Transport Infrastructure

Expressway service areas, toll stations, interchanges, railway facilities, tunnels, airports, and ports.

Renewable Energy Projects

Wind and photovoltaic auxiliary supplies and suitable step-up applications, with transformer ratio, connection scheme, and protection selected for the project.

Technical Specifications

Parameter Specification
HV rated voltage 12 or 24 kV
LV rated voltage 0.4 kV
Rated frequency 50 Hz
Transformer capacity options 630 / 800 / 1000 / 1250 / 1600 / 2000 / 2500 kVA
HV busbar rated current Up to 630 A
LV main busbar rated current Up to 4000 A, matched to transformer capacity and configuration
HV short-time withstand 20 kA for 2 s; peak 50 kA
LV main-circuit short-time withstand 30 kA for 1 s; peak 63 kA
Earthing circuit short-time withstand 17.4 kA for 1 s; peak 43.5 kA
Enclosure protection IP33D; IP44 optional
Compartment protection IP2X and above, according to configuration
Roof distributed load capacity At least 2500 N/m²; additional concentrated loads are not permitted

Configuration selection: Voltage, transformer capacity, HV and LV current ratings, short-circuit withstand, cooling, and enclosure protection are selected together. Higher fault duties and special operating conditions require project-specific verification.

Insulation Levels

Circuit Power-frequency withstand, 1 min Lightning impulse withstand
12 kV HV circuit 42 kV 75 kV
24 kV HV circuit 50 kV 125 kV
LV circuit 2.5 kV 7.4 kV
Auxiliary and control circuits 2.0 kV —

High-altitude insulation requirements are assessed separately for the actual installation altitude and selected equipment.

Construction and Configuration

YB substation internal arrangement of transformer HV and LV compartments

Internal Compartment Arrangement

Select the image to view the full-size illustration.

High-Voltage Unit

Ring-main, terminal, or dual-source arrangements use switch-fuse or circuit-breaker protection. Cable terminations, separable connectors, manual or motorised operation, and metering are selected by scheme.

Transformer Unit

Sealed oil-immersed or dry-type transformers are available. Vector groups include Dyn11 or Yyn0; impedance options include 4%, 4.5%, or 6%, according to capacity and the selected design.

Low-Voltage Unit

Single-busbar or sectionalised-busbar arrangements provide the required incoming supply, outgoing feeders, metering, protection, and reactive compensation.

Enclosure and Auxiliary Systems

A welded channel-steel base supports the enclosure, with lifting points and foundation fixing. Lighting, temperature/humidity control, and maintenance accessories are specified in the supply scope.

Ventilation and Noise Control

Transformer-room louvres and temperature-controlled fans support cooling. Dry-type transformers can include winding-temperature alarms and trip outputs; oil-immersed transformer protection is selected by type and capacity.

A sound level of 51.4 dB(A) was measured for the corresponding type-tested configuration, against a limit of 55 dB(A). Site noise depends on the selected transformer, cooling, operating conditions, and surroundings. Low-noise transformers, silencers, and acoustic measures can be reviewed for sensitive locations.

Protection, Interlocking, and Earthing

Access and operating interlocks are coordinated with the HV scheme and earthing arrangement. A continuous earth busbar connects the equipment enclosures, doors, and relevant foundation parts; transformer-neutral connections follow the specified system design.

Intelligent Monitoring and System Integration

Measurements and Status

Selected HV/LV electrical values, transformer temperature, compartment temperature and humidity, switch positions, fan status, and door indications.

Alarms and Supervisory Communication

Protection indications, condensation alarms, and selected remote switching functions. Communication interfaces and authorised controls are agreed for the project.

Optional Site Functions

Wireless temperature sensing, video surveillance, access control, and perimeter alarms through the selected equipment and system integration.

Site Layout and Foundation

Overall enclosure dimensions depend on transformer capacity, layout, equipment, and access arrangements. We provide the project arrangement and foundation drawings for civil coordination.

YB prefabricated substation foundation plan and section schematic

Foundation Plan and Section

Select the image to view the full-size illustration.

Parameter Specification
Foundation construction Reinforced-concrete base and walls, designed for soil conditions and equipment loads
Top above finished grade Generally 300–500 mm, subject to flood-level and site requirements
Cable routes Reserved ducts or trenches with drainage and coordinated cable supports
Embedded parts Continuous channel steel and fixing interfaces coordinated with the enclosure base
Installation access Space for all doors, operation, maintenance, ventilation, and lifting

The foundation drawing is a schematic. Dimensions, openings, reinforcement, and structural loads follow the approved project drawings. Keep ventilation louvres unobstructed, provide a designed earth grid, and avoid waterlogged locations.

Integral lifting uses the designated base lifting points and the supplied lifting instructions. Inspect level, seating, fixing, earthing, and cable connections before commissioning.

Quality Assurance and Technical Support

Product engineering references GB/T 17467-2020, GB/T 11022-2020, GB/T 7251.8-2020, GB 20052-2020, and GB/T 1094.1-2013. Applicable standards, editions, and transformer energy-efficiency requirements are confirmed for the proposed equipment.

Applicable type-test and certification documents are available for project review. Verification covers the corresponding constructions, including insulation, temperature rise, short-time withstand, enclosure protection, mechanical strength, earthing, and functional tests.

We supply product certificates, factory inspection reports, operating instructions, primary/secondary diagrams, and packing information according to the agreed scope.

Service Conditions

Parameter Specification
Installation Outdoor
Normal ambient temperature −25°C to +40°C
Cold-region option Down to −45°C, by specific agreement
Normal service altitude Up to 1000 m
High-altitude option Dedicated configurations verified at 4500 m; actual altitude to be stated
Relative humidity Daily average ≤95%; monthly average ≤90%
Environment Free from fire/explosion hazards, heavy pollution, and chemical corrosion
Seismic requirements Foundation and anchorage designed for local requirements

State salt fog, sand and dust, heavy condensation, harmonic loads, and unusual temperatures in your enquiry. We coordinate insulation, corrosion protection, filtration, dehumidification, and thermal requirements for the site.

Project Configuration and Enquiry

Discuss Your YB Substation Project

Send your single-line diagram and available site layout. Please include:

  • HV/LV voltages, transformer capacity, quantity, and delivery schedule.
  • Ring-main, terminal, or dual-source HV supply and required protection.
  • LV incomer, feeder circuits, busbar sectioning, compensation, and metering.
  • Oil-immersed or dry-type transformer and required efficiency class.
  • Enclosure material, colour, protection, dimensions, and access requirements.
  • Cable entry/exit mode, sizes, and circuit quantities.
  • Site altitude, temperatures, flood level, corrosion, dust, and noise requirements.
  • Monitoring, communication, video, access control, and auxiliary functions.

If you are still planning your project, send the information you have. We can discuss the remaining details with you.

Prefer email? info@shenglong-hub.com

Specifications and configurations are subject to the approved project technical agreement and final manufacturer confirmation. Test and certification documents apply to their respective equipment and conditions.