SCHNEIDER ELECTRIC LICENSED SYSTEM
MVnex Medium-Voltage Switchgear
Schneider Electric’s indoor metal-clad withdrawable switchgear, manufactured by Shenglong for project-specific medium-voltage distribution.
Select an 800 mm standard or 550 mm compact configuration for the required circuit duty. Shenglong offers type-tested 12 kV configurations. For 24 kV projects, we review the technical requirements and agree the necessary testing programme before supply.

Two Cabinet Formats
800 mm Standard
Project-selected incoming, feeder, and coupling arrangements.
550 mm Compact
Separately tested 12 kV, 1250 A, 31.5 kA configuration.
Choose the configuration around the circuit duty, cable interface, and available space.
ApplicationsCabinet FormatsTechnical Data24 kV EnquiriesConstructionProject Support
Schneider Electric Licensed System, Shenglong Manufacturing
Shenglong supplies MVnex within its current Schneider Electric authorisation scope, with manufacturing and application experience in data centres, cement plants, and industrial projects.
Our 12 kV range includes standard and compact cabinet formats for different circuit duties and installation requirements.
Typical Applications
Data Centres
Medium-voltage incomers, transformer feeders, bus coupling, protection, and metering coordinated with the facility supply and maintenance strategy.
Cement and Process Plants
Medium-voltage distribution for plant transformers and process utilities, with protection coordination and site conditions included in the design.
Industrial Projects
Incoming and outgoing circuits, bus sections, and voltage-measurement functions for manufacturing and other industrial facilities.
Space-Constrained Switchrooms
Selected 550 mm compact cabinets where the required ratings, cable arrangement, operating access, and installation conditions permit.
800 mm Standard and 550 mm Compact
800 mm Standard Configuration

A standard-width format for the selected cabinet function. We coordinate the breaker, current rating, short-circuit duty, instrument transformers, connections, and verification for the proposed equipment.
550 mm Compact Configuration

A narrower format with a separate Shenglong type-test report for MVnex(550)-12/1250-31.5. The verified configuration provides 1250 A current and 31.5 kA / 4 s main-circuit withstand at 12 kV.
Technical Selection Overview
| Parameter | Specification |
|---|---|
| Equipment | Indoor metal-clad withdrawable MVnex switchgear |
| Shenglong type-tested voltage class | 12 kV |
| Cabinet formats | 800 mm standard; 550 mm compact, by configuration |
| 550 mm tested configuration | 12 kV; 50 Hz; 1250 A |
| 550 mm main-circuit short-time withstand | 31.5 kA for 4 s; peak 80 kA |
| 550 mm earthing-circuit short-time withstand | 27.4 kA for 2 s; peak 69.6 kA |
| 550 mm power-frequency withstand | 42 kV for 1 min |
| 550 mm lightning impulse withstand | 75 kV |
| 550 mm enclosure protection | IP4X; IP2X between compartments and with front door open |
| 800 mm electrical ratings | Specified for the selected circuit duty and cabinet configuration |
| Overall depth and height | Confirmed by cabinet function and project arrangement drawings |
The ratings listed for the 550 mm cabinet apply to model MVnex(550)-12/1250-31.5. Ratings for the 800 mm cabinet are confirmed separately during selection.
24 kV Project Enquiries
The MVnex product family includes 24 kV designs. For Shenglong supply, 24 kV projects are handled through a separate technical assessment and agreed verification programme.
Shenglong has completed its own type tests for 12 kV equipment. Type testing for 24 kV equipment can be arranged according to customer requirements, with the test scope and schedule agreed during project planning.
Construction and Operating Features
Metal-Clad Compartmentalisation
Dedicated spaces organise switching equipment, busbars, cables, and low-voltage protection/control devices.
Withdrawable Switching Equipment
Truck positioning, shutters, and operating interlocks support the selected switching and maintenance sequence.
Protection and Metering
Protection relays, instrument transformers, indication, and metering are selected around the circuit duty and project control requirements.
Connection and Access
Cable entry, busbar interfaces, operating clearance, and maintenance access are coordinated with the selected cabinet dimensions.

Project Engineering and Technical Support
We coordinate the single-line diagram, cabinet functions, switching devices, protection, cable routes, earthing, pressure relief, and installation interfaces. Applicable manufacturing authorisation and test documents are provided for project review.
Specify system frequency, ambient conditions, altitude, humidity, corrosion, and seismic requirements. We confirm equipment ratings and any additional verification or protective measures for the site.
Discuss Your MVnex Project
Send your single-line diagram and equipment schedule. Please include:
- Project application, location, quantities, and delivery schedule.
- 12 kV or 24 kV requirement and required verification.
- 800 mm standard or 550 mm compact preference.
- Circuit currents, fault current, withstand duration, and circuit functions.
- Protection, metering, control supplies, and communication interfaces.
- Room layout, cable routes, installation clearances, and site conditions.
If you are still planning your project, send the information you have. We can discuss the remaining details with you.
Prefer email? info@shenglong-hub.com
Ratings and options apply to their respective configurations. Authorised product scope, equipment ratings, documentation, and supply responsibilities are confirmed in the project technical agreement.