KYN28A-12 Medium-Voltage Switchgear

SHENGLONG MEDIUM-VOLTAGE SWITCHGEAR

KYN28A-12 Indoor Metal-Clad Withdrawable Switchgear

Shenglong KYN28A-12 switchgear receives and distributes electrical power in three-phase, 12 kV, 50 Hz systems, providing circuit control, protection, and monitoring.

A compartmentalised cabinet and withdrawable circuit-breaker truck provide dedicated spaces for the main busbars, switching equipment, cable connections, and secondary control circuits.

We configure cabinet arrangements, circuit breakers, protection devices, and connection interfaces to suit your distribution scheme and installation requirements.

Discuss Your ProjectTechnical Specifications

Shenglong KYN28A-12 switchgear brochure cover
Shenglong KYN28A-12 Switchgear

Product FeaturesTypical ApplicationsTechnical SpecificationsCabinet Construction and ConfigurationProduct Details and Wiring SchemesDimensions and Installation LayoutService Conditions

Product Features

Compartmentalised Construction

Separate compartments accommodate the main busbars, circuit-breaker truck, cables, and relay and instrument equipment. The internal arrangement is selected together with the circuit function and installed components.

Withdrawable Circuit-Breaker Truck

Defined service and test/disconnected positions support equipment operation, inspection, and maintenance. Truck construction and interchangeability are matched to the selected equipment and ratings.

Mechanical Interlocking

Interlocks coordinate the circuit-breaker truck, circuit breaker, earthing switch, and relevant access doors. We select the interlocking scheme to suit the required operating sequence.

Protection and Monitoring

The relay and instrument compartment accommodates protection relays, meters, indication devices, and secondary wiring. Protection functions, alarms, measurements, and communication interfaces are specified for each project.

Typical Applications

KYN28A-12 switchgear can be configured for the following medium-voltage distribution applications.

Industrial Power Distribution

Medium-voltage distribution for manufacturing plants, metallurgical facilities, petroleum and chemical facilities, cement plants, and other industrial installations.

Substations and Distribution Stations

Incoming and outgoing feeders, bus coupling, metering, voltage-transformer, and station-service circuits arranged around the project single-line diagram.

Commercial and Public Buildings

Medium-voltage power distribution for commercial complexes, high-rise buildings, hospitals, and other public facilities.

Transport Infrastructure

Medium-voltage distribution systems serving airports, ports, railway facilities, and urban rail projects. Dedicated traction equipment requirements are reviewed separately.

Renewable Energy Projects

Collection and distribution circuits in wind and photovoltaic projects where the required equipment voltage, current, and short-circuit duty match the selected switchgear configuration.

Project Engineering

We coordinate cabinet functions, protection and metering, cable or busbar connections, room layout, and installation interfaces for the proposed application.

Select the 12 kV equipment class to match the system voltage and insulation requirements. Suitability also depends on the circuit arrangement, rated current, short-circuit duty, service environment, and installation conditions.

Technical Specifications

The following parameters provide an overview for configuration selection. Electrical ratings, components, and enclosure construction are coordinated for the proposed equipment.

Parameter Specification
Product series KYN28A-12
Equipment type Indoor metal-clad withdrawable AC switchgear
System application Three-phase, 12 kV, 50 Hz
Main compartments Busbar; circuit-breaker truck; cable; relay and instrument
Standard enclosure protection IP4X enclosure; IP2X between compartments and with the circuit-breaker compartment door open
IP54 configuration Available according to the selected enclosure construction and project requirements
Circuit-breaker and current ratings Selected according to the circuit duty and agreed technical schedule
Cable and busbar interfaces Cable and overhead connection arrangements, according to the selected cabinet configuration
Rating selection: Rated current, short-time and peak withstand currents, withstand duration, insulation levels, circuit-breaker ratings, and enclosure protection are specified together for the selected configuration.

Cabinet Construction and Configuration

The withdrawable construction provides access to functional units for inspection and maintenance. Dedicated compartments organise the primary circuit, cable connections, protection, and control wiring.

Primary Circuit Arrangement

Incoming, outgoing, and bus-coupling circuits are configured around the project single-line diagram. Circuit breakers, instrument transformers, earthing arrangements, protection, and metering are selected to match the circuit requirements.

Connection and Access Requirements

Cable and overhead connections are arranged to suit the installation. Cabinet function, selected components, cable access, operating space, and pressure-relief requirements are coordinated during project engineering.

Product Details and Wiring Schemes

Shenglong KYN28A-12 product image 2

KYN28A-12 — View 1

Product illustration. Cabinet arrangement and installed equipment depend on the selected configuration.

Shenglong KYN28A-12 product image 3

KYN28A-12 — View 2

Product illustration. Cabinet arrangement and installed equipment depend on the selected configuration.

KYN28A-12 primary single-line wiring scheme diagrams

Primary Wiring Schemes

Typical primary single-line diagrams. Circuit arrangements and components are selected to match the project single-line diagram and protection requirements.

Dimensions and Installation Layout

We coordinate the switchroom layout, foundation openings, cable trenches, and connection interfaces with your civil and electrical design. Select each drawing to open the full-size image.

KYN28A-12 switchroom plan showing switchgear arrangement, power cable trench and control cable trench

Switchroom Layout

Typical arrangement of the switchgear, power cable trench, and control cable trench.

KYN28A-12 switchgear base plate openings and fixing dimensions for primary and secondary cables

Foundation Openings

Primary and secondary cable openings and fixing dimensions.

KYN28A-12 switchroom section A-A showing foundation frame, cable trenches and installation dimensions

Switchroom Section

Section A–A showing the foundation frame and cable trench arrangement.

KYN28A-12 switchgear cable trench layout with foundation frame and fixing dimensions

Cable Trench Layout

Foundation frame, cable trench, and fixing dimensions.

Installation drawings: Final dimensions and clearances are confirmed in the approved project drawings. Some annotations in the foundation-opening, switchroom-section, and switchroom-plan illustrations are obscured or incomplete; obtain the complete project drawings before civil construction or installation.

Quality Assurance and Technical Support

We support your project with product specifications, cabinet arrangement drawings, installation information, and applicable test documentation.

Enclosure Protection

KYN28A-12 is available with IP54 enclosure configurations for projects requiring enhanced protection against dust and water ingress. We select the enclosure construction together with ventilation, thermal performance, and site requirements.

Safety and Performance Verification

Applicable test documentation is available to support the review of enclosure protection and protection of persons against dangerous electrical effects. We coordinate the required verification documents with your project specification and selected equipment.

Contact us to request technical documents for your proposed configuration.

Service Conditions

KYN28A-12 is intended for indoor installation. We review the operating environment together with the electrical and installation requirements.

  • Installation altitude and ambient temperature range.
  • Humidity and condensation risk.
  • Pollution and corrosive conditions.
  • Seismic and anchorage requirements.
  • Ventilation, heat dissipation, and pressure-relief requirements.

Special service conditions may require derating, additional insulation measures, ventilation, or enclosure treatment. Include these conditions in your enquiry so that the appropriate configuration can be selected.

Project Configuration and Enquiry

Send us your single-line diagram, equipment schedule, and available installation drawings. We will review the cabinet arrangement, electrical ratings, protection, and connection requirements with you.

Electrical Requirements

  • System voltage and frequency.
  • Required rated current.
  • Short-circuit duty and withstand duration.
  • Incoming, outgoing, and bus-coupling circuits.
  • Circuit-breaker, protection, and metering requirements.

Installation and Project Information

  • Project location, quantities, and delivery schedule.
  • Switchroom layout and available space.
  • Cable entry and busbar connection details.
  • Enclosure protection and site conditions.
  • Communication interfaces and required technical documents.

Discuss Your KYN28A-12 Switchgear Project

Contact us with your electrical specifications, single-line diagram, and installation requirements. We can discuss suitable cabinet configurations, protection equipment, connection arrangements, and technical documentation for your application.

If you are still planning your project, send the information you have. We can discuss the remaining details with you.

Prefer email? info@shenglong-hub.com

Technical specifications and configuration options are subject to the approved project technical agreement and final manufacturer confirmation. Test documents apply to their respective tested constructions and rated ranges.

← Back to Medium-Voltage Switchgear