GCS Low-Voltage Withdrawable Switchgear

SHENGLONG LOW-VOLTAGE SWITCHGEAR

GCS Low-Voltage Withdrawable Switchgear

Shenglong GCS switchgear provides electrical power distribution, motor control, and reactive power compensation for industrial and commercial power systems.

A modular cabinet structure, withdrawable functional units, and flexible circuit arrangements accommodate incoming supplies, bus coupling, outgoing distribution, and motor control.

We configure cabinet lineups to suit your electrical ratings, circuit requirements, and installation conditions.

Discuss Your ProjectTechnical Specifications

GCS low-voltage withdrawable switchgear cabinet
GCS Low-Voltage Switchgear. Cabinet arrangements are selected for each project.

Product FeaturesTypical ApplicationsTechnical DataFunctional UnitsEquipment PhotosInstallationService Conditions

Product Features

Modular Cabinet Construction

An assembled C-section steel frame accommodates different cabinet and functional-unit configurations. Removable hinge arrangements facilitate door installation and maintenance.

Compartmentalised Design

Dedicated spaces accommodate horizontal busbars, electrical equipment, cables, and control circuits. Physical separation organises the assembly and helps limit fault propagation.

Withdrawable Functional Units

Primary plug-in connections link functional units to the distribution busbars. Standardised units of the same specification and corresponding primary and secondary connections can be interchanged.

Three-Position Drawer Operation

Connected: main and secondary circuits connected. Test: main circuit disconnected while the secondary circuit remains connected. Isolated: both main and secondary circuits disconnected.

Busbar System

Rectangular copper vertical busbars are installed within flame-retardant functional boards. The supporting structure provides insulation and mechanical support against short-circuit forces.

Flexible Cabinet Arrangements

Withdrawable and fixed-compartment configurations can be combined in a lineup. Incoming, outgoing, motor-control, and compensation circuits follow the project single-line diagram.

Mechanical and Electrical Interlocking

Mechanical interlocking is supplemented by electrical interlocking. Specified three-source supply interlocking arrangements can be configured for the project.

Neutral and Protective Conductors

GCS supports three-phase four-wire and five-wire systems. Separate neutral and protective-earth conductors are provided for TN-S arrangements; combined PEN arrangements can be provided for TN-C systems. Connections are defined during engineering.

Typical Applications

Industrial Facilities

Power distribution and motor control in petroleum, chemical, metallurgical, mining, textile, and general manufacturing facilities.

Power Plants and Substations

Low-voltage distribution, auxiliary power supplies, incoming circuits, bus coupling, and outgoing feeders.

Commercial and Public Buildings

Low-voltage distribution in high-rise buildings, commercial complexes, and other building installations.

Data Centres and Compensation Systems

Distribution circuits for data-centre facilities and industrial power-factor compensation systems, selected for the required operating and protection scheme.

Suitability is reviewed against the system voltage, load, short-circuit duty, continuity requirements, and installation conditions.

Technical Specifications

The applicable ratings depend on cabinet construction, busbars, functional units, and project requirements.

Parameter Specification
Product designation GCS
Equipment type AC low-voltage withdrawable switchgear
Main-circuit rated voltage 380 / 400 V AC; 800 V available as an option
Rated frequency 50 / 60 Hz
Rated insulation voltage 660 / 690 / 1140 V
Auxiliary-circuit rated voltage 220 / 380 / 400 / 500 / 690 V AC; 110 / 220 V DC
Horizontal busbar rated current Up to 4000 A
Vertical busbar rated current, MCC Up to 2000 A
Busbar short-time withstand current 30 / 50 / 80 kA for 1 s
Busbar peak withstand current 63 / 105 / 176 kA; specified duration 0.1 s
Power-frequency withstand voltage, 1 min Main circuit: 2500 V; auxiliary circuit: 1760 V
Enclosure protection IP30 / IP31 / IP32 / IP40 / IP41 / IP42
Mechanical impact rating Up to IK10
Basic functional-unit height module E = 25 mm

Rating selection: Horizontal and vertical busbar ratings are separate from individual circuit ratings. Functional-unit capacity depends on configuration and thermal derating. Operational voltage and insulation voltage are selected separately.

Cabinet Structure and Functional Units

Power Distribution Centre Compartments

  • Horizontal busbars at the top of the cabinet.
  • Electrical equipment at the front or front-left section.
  • Cable space at the lower front or front-right section.
  • Control circuits in the middle or upper front section.

Withdrawable Drawer System

With a basic module of E = 25 mm, standard unit heights include 6E, 8E, 10E, and 16E. Half-unit arrangements such as 8E/2 are also available. Unit combinations depend on the selected components, rated current, available space, and thermal requirements.

GCS withdrawable functional drawer unit

Withdrawable Functional Unit

Modular drawer construction with primary and secondary plug-in connections.

GCS withdrawable outgoing feeder cabinet structure

Withdrawable Outgoing Feeder Cabinet

Drawer-based outgoing distribution and motor-control arrangement.

Fixed-Compartment Configuration

Fixed-mounted components are arranged in separate compartments with front access for operation and maintenance. Configurations up to 24E / 800 A are available according to the selected arrangement. Fixed and withdrawable cabinets can be combined in a lineup.

GCS fixed-compartment outgoing feeder cabinet structure

Fixed-Compartment Outgoing Feeder Cabinet

Dedicated fixed-mounted compartments for power distribution.

GCS Cabinets and Withdrawable Units

GCS incoming cabinet with front switching, indication, and metering equipment.

Incoming Cabinet

GCS incoming cabinet with front switching, indication, and metering equipment.

GCS withdrawable-unit front panels with operating handles and metering.

Withdrawable-Unit Front Panels

GCS withdrawable-unit front panels with operating handles and metering.

A GCS functional unit in the withdrawn position, showing the front panel and internal arrangement.

Withdrawable Functional Unit

A GCS functional unit in the withdrawn position, showing the front panel and internal arrangement.

Primary connections and current-transformer arrangement inside a GCS functional unit.

Internal Connection Detail

Primary connections and current-transformer arrangement inside a GCS functional unit.

Cabinet Functions

Power Distribution

Incoming supplies, bus couplers, and outgoing feeders are configured with circuit breakers, current transformers, metering, protection, and control equipment.

Motor Control

Motor-control units can incorporate circuit breakers, contactors, overload protection, and control components. Motor ratings, starting methods, control supplies, and circuit quantities are selected together.

Reactive Power Compensation

Capacitor banks, controllers, switching steps, and protective devices are selected for the system load and required compensation capacity. A typical power-factor target is at least 0.9 under normal compensation control operation; actual performance depends on the design and load conditions.

Dimensions and Installation Planning

Parameter Specification
Cabinet widths 600 / 800 / 1000 mm
Cabinet depths 600 / 800 / 1000 mm
Cabinet height 2200 mm

Available width and depth combinations depend on cabinet function. Lineups can be arranged in single rows or face-to-face double rows, with access, cable entry, and busbar connections coordinated for the site.

Overhead busbar bridges and connections to transformers, adjacent switchboards, or busduct systems are defined during engineering.

Standards, Testing and Technical Support

GCS engineering references GB 7251.1, IEC 61439, and GB 24274. Applicable standards and editions are confirmed for the proposed equipment.

Applicable type-test reports and CQC certification documentation are available for project review. Product certificates, factory inspection reports, wiring diagrams, and other documents are supplied according to the agreed scope.

Factory Routine Inspection

Routine inspection includes enclosure and marking checks, protective-earthing continuity, dielectric tests, mechanical operation, and verification of secondary wiring and indication circuits.

Service Conditions

Parameter Specification
Installation Indoor
Ambient temperature −5°C to +40°C
24-hour average temperature Not more than +35°C
Relative humidity Not more than 50% at +40°C; higher humidity permitted at lower temperatures, such as 90% at +20°C
Altitude Not more than 2000 m
Environment Without fire or explosion hazards, severe dust, severe vibration, or direct exposure to rain

Prevent condensation through appropriate ventilation, air conditioning, or dehumidification. Higher altitudes, elevated temperatures, salt-laden atmospheres, and corrosive conditions require review of insulation, thermal performance, enclosure construction, and derating.

Project Configuration and Enquiry

Send your single-line diagram and electrical specifications so we can review suitable cabinet functions, unit arrangements, and installation interfaces.

Discuss Your GCS Switchgear Project

Please include the following information where available:

  • Project location, application, quantities, and delivery schedule.
  • Operational voltage, frequency, earthing system, and busbar currents.
  • Short-circuit withstand current and duration.
  • Incoming, outgoing, bus-coupler, and motor-control circuits.
  • Withdrawable or fixed units, unit sizes, and enclosure protection.
  • Motor starting, metering, control, communication, and compensation requirements.
  • Cabinet layout, cable entry, transformer and busbar-bridge connections.
  • Altitude, temperature, humidity, and other site conditions.

If you are still planning your project, send the information you have. We can discuss the remaining details with you.

Prefer email? info@shenglong-hub.com

Technical specifications and configuration options are subject to the approved project technical agreement and final manufacturer confirmation. Test and certification documents apply to their respective configurations and rated ranges.