KYN61-40.5 Medium-Voltage Switchgear

SHENGLONG MEDIUM-VOLTAGE SWITCHGEAR

KYN61-40.5 Indoor Metal-Clad Withdrawable Switchgear

Shenglong KYN61-40.5(Z) receives and distributes electrical power in three-phase, 50/60 Hz systems with a rated voltage of 40.5 kV, providing circuit control, protection, and monitoring.

Single-busbar and sectionalised single-busbar arrangements accommodate incoming, outgoing, bus-coupling, isolation, voltage-measurement, and station-service circuits.

We configure electrical ratings, protection, cabinet functions, and connection interfaces around your project requirements.

Discuss Your ProjectTechnical Specifications

KYN61-40.5 indoor switchgear lineup
KYN61-40.5 switchgear. Cabinet configurations are selected for each project.

Product FeaturesTypical ApplicationsTechnical DataCabinet StructureWiring SchemesInstallationService Conditions

Product Features

Metal-Clad Construction

A 2.0 mm aluminium-zinc-coated steel enclosure and metal compartment partitions form a bolted/riveted cabinet, with separate spaces for busbars, the circuit-breaker truck, cables, and low-voltage equipment.

Withdrawable Circuit-Breaker Truck

A screw-driven racking mechanism moves the truck between service and test/isolation positions. Trucks of the same rating and compatible construction are interchangeable.

Automatic Shutters and Interlocking

Shutters cover the fixed contacts when the truck is withdrawn. Mechanical and electrical interlocks coordinate the circuit breaker, truck, earthing switch, and secondary connector.

Insulation and Pressure Relief

Internal air clearances are at least 300 mm. Independent pressure-relief ducts are provided for the main compartments, with the venting route coordinated with the room layout.

Protection and Monitoring

The low-voltage compartment accommodates protection, control, metering, and indication. Optional temperature measurement, partial-discharge monitoring, sequence control, and arc protection are defined in the project scope.

Earthing and Condensation Control

A 6 × 50 mm copper earth bar connects adjacent panels. Heaters and dehumidification equipment help manage humidity, condensation, and corrosion.

Typical Applications

Industrial Power Distribution

Medium-voltage distribution for metallurgy, petrochemical, chemical, paper, cement, textile, automotive, natural-gas, and semiconductor facilities.

Power Plants and Substations

Incoming supplies, feeders, bus sections, isolation, metering, and station-service circuits in power plants, substations, switching stations, and distribution stations.

Infrastructure and Public Facilities

Suitable medium-voltage distribution circuits serving airports, ports, railway facilities, hospitals, commercial complexes, and high-rise buildings.

Renewable Energy Projects

Wind and photovoltaic step-up and collection systems where the equipment voltage, current, and short-circuit duty match the required circuit configuration.

Application suitability is confirmed against the system voltage, load, fault level, operating requirements, and site conditions.

Technical Specifications

Parameter Specification
Product designation KYN61-40.5(Z)
Equipment type Indoor metal-clad withdrawable AC switchgear
Rated voltage 40.5 kV
Rated frequency 50 / 60 Hz
Rated current 1250 / 1600 / 2000 / 2500 / 3150 A
Main-circuit short-time withstand current 25 / 31.5 kA for 4 s
Main-circuit peak withstand current 63 / 80 kA, corresponding to the selected withstand class
Power-frequency withstand voltage 95 kV for 1 min, to earth / between phases / across gap
Lightning impulse withstand voltage 185 kV, to earth / between phases / across gap
Auxiliary and control circuit withstand voltage 2000 V for 1 min
Enclosure protection IP3X; IP2X between compartments and with the circuit-breaker compartment door open
Internal arc withstand 31.5 kA for 1 s; applicable tested construction and installation conditions to be confirmed
Overall dimensions, W × D × H 1400 × 2750 / 2800 / 3050 / 3200 × 2600 mm
Approximate weight 1000–2000 kg, depending on scheme

Cooling and rating selection: 1250–2000 A arrangements use natural cooling with cabinet depths of 2750 / 2800 mm. 2500–3150 A arrangements require forced air cooling, with 31.5 kA / 4 s withstand duty, 80 kA peak withstand, and cabinet depths of 3050 / 3200 mm. Final combinations are confirmed in the project technical schedule.

Cabinet Structure and Equipment

KYN61-40.5 cabinet compartment cross-section

Cabinet Construction

Select the image to view the original drawing.

Busbar Compartment

Rounded-corner copper main and branch busbars are supported by partitions and bushings. Heat-shrink sleeving and insulated joint shrouds cover the conductor system.

Circuit-Breaker Compartment

Truck rails, automatic shutters, a screw-driven mechanism, secondary plug, and observation window support defined truck positioning and closed-door operation.

Cable Compartment

Current transformers, the earthing switch, cable terminations, voltage transformers, surge arresters, and the earth bar are selected by circuit duty. A removable bottom cover facilitates cable installation.

Low-Voltage Compartment

Relay protection, control units, instruments, terminals, and indication devices are arranged separately from the high-voltage circuit, with dedicated secondary wiring ducts.

Component and Secondary Interfaces

A ZN85-40.5 vacuum circuit breaker is available, with alternatives agreed for the selected configuration. Typical instrument transformer types include LZZB9-35D current transformers and JDZXP-35 voltage transformers. Ratios, accuracy classes, burdens, and quantities follow the circuit design.

Control supplies are selectable at 110 / 220 V AC or DC. Secondary terminal definitions, spring-charging supplies, interlocks, and communication functions are coordinated with the selected devices.

Primary Wiring Schemes

Schemes 001–030 cover cable incoming/outgoing circuits, bus coupling, isolation, PT, metering, and fuse arrangements. Provide your single-line diagram alongside the required circuit functions.

KYN61-40.5 primary wiring schemes 001 to 010

Primary Wiring Schemes 001–010

Select the image to view the original drawing.

KYN61-40.5 primary wiring schemes 011 to 020

Primary Wiring Schemes 011–020

Select the image to view the original drawing.

KYN61-40.5 primary wiring schemes 021 to 030

Primary Wiring Schemes 021–030

Select the image to view the original drawing.

Typical System Arrangements

KYN61-40.5 typical single-incomer single-busbar diagram

Single-Busbar Application Example

Select the image to view the original drawing.

KYN61-40.5 typical sectionalised single-busbar diagram

Sectionalised-Busbar Application Example

Select the image to view the original drawing.

These are circuit examples. Component quantities, ratings, protection, and operating sequences are selected for the project.

Dimensions and Installation Planning

Parameter Specification
Panel width 1400 mm
Panel depth 2750 / 2800 / 3050 / 3200 mm
Panel height 2600 mm
Single-row front operating aisle At least 3000 mm
Rear maintenance aisle 1500 mm
Panel end to wall 1500 mm
Room clear height At least 4500 mm
Face-to-face double-row operating aisle At least 4000 mm

Room clearances, access, floor loading, cable trenches, and overhead busbar connections are coordinated in the approved installation drawings. Keep the top pressure-relief route free of cable trays, pipework, and other obstructions.

KYN61-40.5 switchroom layout with cable trenches

Switchroom Layout

Select the image to view the original drawing.

KYN61-40.5 switchroom section A-A

Switchroom Section

Select the image to view the original drawing.

KYN61-40.5 installation foundation and base-plate openings

Foundation and Base-Plate Openings

Select the image to view the original drawing.

Foundation and Cable Interfaces

An 8# channel-steel foundation frame is used, with its top 15–20 mm above the finished floor. Frame level error is limited to 1 mm/m. Separate power and control cable trenches are provided; the control trench is 250 × 250 mm with a 5 mm checkered-steel cover.

Base-plate interfaces include a front-left secondary cable opening of 300 × 150 mm, a primary cable opening of 650 × 1000 mm, and 8-M8 anchor fixing. Confirm every opening and fixing position against the approved cabinet and civil drawings before construction.

Quality Assurance and Project Documentation

Product engineering references GB/T 3906-2020, GB/T 11022-2020, DL/T 404-2018, and IEC 62271-200. Applicable standards and editions are agreed for the proposed equipment.

We provide technical specifications, cabinet arrangement drawings, installation information, primary and secondary wiring diagrams, and applicable test documentation for project review. Certificates of conformity and factory test reports are supplied according to the agreed documentation scope.

Internal-arc withstand and short-time withstand are different duties. We confirm the applicable tested construction, ratings, and installation conditions for your specification.

Service Conditions

Parameter Specification
Installation Indoor, dry, clean, and well ventilated
Ambient temperature −10°C to +40°C
24-hour average temperature Not more than +35°C
Relative humidity Daily average ≤95%; monthly average ≤90%
Normal service altitude Up to 1000 m
Seismic intensity Not more than intensity 8
Environment Free from fire and explosion hazards, heavy pollution, chemical corrosion, and severe vibration

For high altitude, salt fog, elevated humidity, or other special conditions, we review insulation, thermal performance, condensation control, and any required derating with you.

Project Configuration and Enquiry

Send your single-line diagram, equipment schedule, and room layout so we can review circuit functions, current ratings, cooling, protection, cable interfaces, and installation requirements.

Discuss Your KYN61-40.5 Project

  • Project location, application, quantities, and delivery schedule.
  • System voltage, frequency, current, short-circuit duty, and duration.
  • Incoming, outgoing, bus-coupling, PT, metering, and station-service circuits.
  • Circuit-breaker, protection, metering, and auxiliary supply requirements.
  • Cabinet arrangement, cable specifications, busbar bridges, and site interfaces.
  • Forced cooling for 2500 A and above, monitoring, interlocks, and accessories.
  • Altitude, temperature, humidity, and other special service conditions.
  • Required test documents, drawings, and submission requirements.

If you are still planning your project, send the information you have. We can discuss the remaining details with you.

Prefer email? info@shenglong-hub.com

Technical specifications and configuration options are subject to the approved project technical agreement and final manufacturer confirmation. Test documentation applies to the corresponding tested construction and rated range.

← Back to Medium-Voltage Switchgear