Blokset Low-Voltage Switchgear

SCHNEIDER ELECTRIC LICENSED SYSTEM

Blokset Low-Voltage Switchgear

Schneider Electric’s modular switchgear system for power distribution, motor control, reactive compensation, and selected drive applications.

Shenglong combines authorised Blokset manufacturing with its own type-test experience, project engineering, and manufacturing capability to support demanding distribution and motor-control applications.

Discuss Your ProjectTechnical Specifications

Blokset modular low-voltage switchgear lineup
Representative Blokset system arrangement. Project layouts are selected individually.

ApplicationsSystem FeaturesCabinet TypesTechnical DataInstallationProject Support

Authorised Manufacturing and Project Experience

Shenglong manufactures Blokset within its current Schneider Electric authorisation scope. Our delivery capability combines the licensed system design with project engineering, manufacturing, testing, and technical documentation.

Shenglong Type-Test Experience

Shenglong-manufactured Blokset configurations have undergone type testing. We provide the applicable verification documents for the selected assembly.

Typical Applications

Data Centres

Low-voltage incoming supplies, bus coupling, outgoing distribution, metering, and monitoring coordinated with the required operating and maintenance strategy.

Cement Plants

Distribution and motor control for process equipment and utilities, with drive loads, protection, heat dissipation, and dust exposure addressed in the project design.

Industrial Facilities

Distribution, motor starting, variable-speed drives, and compensation in manufacturing and other industrial installations.

Commercial and Infrastructure Projects

Switchboard lineups configured around load schedules, installation space, cable interfaces, and planned maintenance requirements.

Shenglong has manufacturing and application experience with Blokset in data centres, cement plants, and other industrial projects. Contact us to discuss relevant available project reference information.

Modular Design and Cabinet Functions

Blokset circuit-breaker installation arrangement

Power Distribution

Incoming, outgoing, and bus-coupling circuits with selected fixed or withdrawable switching devices.

Blokset main and distribution busbar system

Busbar System

Main and distribution busbars are engineered with the selected current rating, fault duty, cabinet dimensions, and connections.

Blokset withdrawable motor-control units

Motor Control

Fixed and withdrawable units accommodate motor protection, operating needs, internal separation, and maintenance access.

Blokset power factor correction cabinet arrangement

Power Factor Correction

Compensation capacity, steps, switching devices, and harmonic mitigation are selected for the load.

Cabinet Types

Type Function
D Power distribution
Dc Power factor correction
Mf Fixed motor control centre
Mw Withdrawable motor control centre
Ms Variable-speed drives and starters

Technical Specifications

The following system options are selected together with the applicable Shenglong assembly construction and verification.

Parameter System Specification
System Schneider Electric Blokset
Rated operational voltage Up to 690 V AC; project voltage specified with the selected configuration
Rated insulation voltage 1000 V AC
Rated impulse withstand voltage 12 kV
Overvoltage category IV
Degree of pollution 3
Single main busbar arrangement Up to 4000 A
Double main busbar arrangement Up to 6300 A; excluding type Dc
Single main busbar short-time withstand options 30 / 50 / 85 kA RMS for 1 s, according to arrangement
Single main busbar peak withstand options 63 / 105 / 187 kA peak, according to arrangement
Double main busbar short-time withstand capability 100 kA RMS for 1 s for the specified arrangement
Double main busbar peak withstand capability 220 kA peak for the specified arrangement

Main busbar ratings are separate from individual circuit ratings. Maximum voltage, current, short-circuit duty, protection, and cabinet size are coordinated as a complete configuration.

Enclosure Protection and Internal Separation

Parameter Specification
D / Mf IP20 / IP31 / IP42 / IP54; Form 1 / 2b / 3b / 4
Mw IP20 / IP31 / IP42 / IP54; Form 3b / 4
Ms IP20 / IP31 / IP42; Form 1 / 2b / 3b / 4
Dc IP20 / IP31; Form 1 / 2b

Protection and separation options depend on cabinet type, installed equipment, ventilation, and the selected verified construction.

Dimensions and Installation Planning

Typical cabinet height is 2200 mm. Width and depth combinations depend on function, busbars, cable space, and thermal requirements.

Parameter Specification
D cabinet Widths 700 / 900 / 1100 / 1200 / 1300 mm; depths 400 / 600 / 1000 mm
Dc cabinet Width 700 mm; depths 400 / 600 mm
Mf cabinet Widths 700 / 900 / 1100 / 1300 mm; depths 400 / 600 / 1000 mm
Mw cabinet Widths 500 / 700 / 900 mm; depths 600 / 1000 mm
Ms cabinet Widths 700 / 900 / 1100 mm; depths 400 / 600 / 1000 mm

We provide project arrangement drawings and coordinate cable/busduct interfaces, access, transport sections, ventilation, and foundation requirements.

Testing, Documentation, and Service Conditions

We support selection and project submissions with authorisation information, applicable type-test documents, arrangement drawings, and installation requirements.

State ambient temperature, altitude, humidity, dust, corrosion, and seismic requirements during enquiry. The relevant assembly construction, thermal rating, and protective measures are selected for the actual site.

System images are representative illustrations; components and layouts vary with the selected project configuration.

Discuss Your Blokset Project

Send your single-line diagram and equipment schedule. Please include:

  • Project location, application, quantities, and delivery schedule.
  • Voltage, frequency, earthing system, currents, and fault duty.
  • Incoming/outgoing, bus coupling, motors, drives, and compensation.
  • Internal separation, enclosure protection, monitoring, and interfaces.
  • Applicable project standards, test documents, and submission requirements.
  • Cabinet layout, connections, access, and service environment.

If you are still planning your project, send the information you have. We can discuss the remaining details with you.

Prefer email? info@shenglong-hub.com

Ratings and options apply to their respective configurations. Authorised product scope, equipment ratings, documentation, and supply responsibilities are confirmed in the project technical agreement.

← Back to Licensed Switchgear Systems